445-470nm blue light&650-1100nm near-infrared light,BP460nm+ LP650nm Dual band Filter

  • 450nm bandpass filters
  • BP460nm + LP650nm dual-band filter
Product features

● Dual-band design, blue&infrared light

● Central wavelength accuracy

● High Peak Transmittance

● Deep cut-off depth

● Multiple substrates available

● Advanced Coating Technology

● Wide range of applications

Product Detail

Product Descriptions:
Characteristics:BP460nm+ LP650nm Dual band Filter
Type:Interference type Filter
Central Wavelength(in nm):460nm, 650nm
Average Transmittance(%) :>92%
Full Width at Half Maximum(FWHM):25nm
Optical Density (OD):OD2 – OD3
Shape:Round, Square or customized.
Color:Blue
Angle of Incidence(AOI):0° or customized
Surface Quality:60/40 scratch-dig
Dimension(mm):Customized, max. 300x300mm
Thickness(mm):0.21、0.3、0.55、0.7、1.0、1.1、1.5、1.8、2.0、3.0mm…etc.
Substrate materials:Ultra-clear glass,K9,BK7,B270,D2637T, Quartz Glass(Fused Silica) or other specified.
Remark: Support customized for wavelength from 200-2000nm.
Measured Spectral Graph
Picture 1: BP460nm+ LP650nm Dual band Filter spectral graph measurement
What is typical application for BP460nm + LP650nm Dual band Filter

Typically, the BP460nm + LP650nm dual-band filter is mainly on application for multi-color fluorescence imaging and flow cytometry, where it simultaneously captures blue light and near infrared light signals in a single optical path. Besides, this filter also for multispectral analysis, dual-wavelength illumination systems, and laser beam combining for biomedical and industrial inspection applications.

What is key parameter when choose for suitable Dual band Filter?

When selecting a Dual Bandpass Filter, normally the following factors need to be taken into consideration:

  • Central Wavelength (CWL):Firstly, CWL is one of key parameter to designate, it refer to the central wavelength at stable high transmission rate passband.
  • Peak or Average Transmittance(in %): typically ≥90%, Higher transmittance might need Anti-reflective(AR) coating.
  • Full width at half maximum (FWHM): it refer to the interval between the two wavelength points where the transmittance rate reaches 50%.
  • Blocking rate: usually in terms of optical density(OD), OD2-OD3 for standard and higher blocking rate will be OD4-OD6 per requirement.
  • Angle of Incidence (AOI): AOI need to be considered as Interference Filter is angle sensitive, 0° AOI  by default, other AOI e.g. 30/45° need to be specified.
  • Physical and environmental requirement: Substrate type, dimensions and thickness, surface quality, and environmental durability.
Related products:

BP450+815nm Dual Bandpass Filters, Support Customized

 

650&850nm Dual Bandpass Filter, 40nm FWHM,Day&Night Optical Filter

BP530-650 & 900-1800nm AR coating Dual Bandpass Filters

Shenzhen Hengda Liyuan Optoelectronics introduced advanced optical vacuum technology that apply depositing nano-materials through ion-assisted evaporation onto a multilayer hard film in a high vacuum environment which coating layer is firm and has good tightness, and small bandwidth drift. Besides, Liyuan optoelectronics have been focus on optical coating for more than 17 years ,and the company offer one-stop optical filters solution including Narrow Bandpass Filters, IR cut-off Filters, Longpass Filters, Shortpass Filters, Notch Filters, ND filters, Star filters and Optical sapphire block.